33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 6 patents, you can check the Audit Report for more information
to see all verified strength labels (27)
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
  • 33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
RCW33
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
MCB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000
Material
Steel
Rating Frequency
50Hz
Rated Current
630-4000A
Transport Package
Wooden
Trademark
Chenghe
Origin
Wenzhou China
Production Capacity
4000 Sets/Year

Product Description

 

General

Chenghe Electric strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.

The RCW series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. and its rated current can reach 1250A.

The RCW series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.


Service environment

  a) Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
  b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  c) Altitude above sea level: Maximum installation altitude:2500mor more higher.
  d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  e) No frequent violent shake
Product Parameters

Main technical data

 
No. item unit data
1 Rated voltage kV 15 27 38
2 Rated current A 630 1250 800
3 Rated frequency Hz 50/60
4 Power frequency 1 min Dry kV 50 65 85
Wet kV 45 55 75
5 Lightning impulse withstand voltage(peak value) alternate, opposite/fracture kV 100 125/150 170
6 Rated short circuit breaking current kA 20 16/25 12.5
7 Rated short current switching current(peak value) kA 50 40/63 31.5
8 Rated peak value withstand current kA 50 40/63 31.5
9 4S short time withstand current kA 20 16/25 12.5
10 Rated operating circulate   O-T1-CO-12s-CO-12s-CO-12s-CO
11 Breaking current frequency under rated short circuit times 30
12 Mechanism life times 10000
13 Secondary loop 1 min power frequency withstand voltage   2
 
33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller
33kv Outdoor Auto Circuit Recloser ACR with Kema Test Report with Smart Controller

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier