Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit

Product Details
Customization: Available
Certification: VDE, CCC, ISO9001
Shell Material: Aluminum Alloy
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 6 patents, you can check the Audit Report for more information
to see all verified strength labels (27)
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
  • Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
Find Similar Products

Basic Info.

Model NO.
RMR
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Withdrawable
Current
AC
Protection Level
IP4X
Application
Electric Power Transmission
Form
Distribution Box Electrical Boxes
Transport Package
Wooden
Trademark
Chenghe
Origin
Wenzhou China
Production Capacity
4000 Sets/Year

Product Description

Product Description

 Sf6 RMR Ring Main Unit Switchgear

Product Description
iSafering SF6 insulated Ring Main Unit
Gas Insulated Ring Main Unit


iSafeRing is a SF6 insulated ring main unit for the secondary distribution network. iSafeRing can be supplied in 10 different configurations suitable for most switching applications in 12/24/36 kV distribution networks. As an option, iSafeRing can be delivered as extendable ring main unit.

Together, iSafeRing represent a complete solution for 12/24/36 kV secondary distribution networks.
C - Cable switch module F - Cable switch module V - Cable switch module
D - Direct cable connection module De - Direct cable connection module with earthing switch M - Metering module

Modularity and external busbar

All modules except the metering module and circuit-breaker module are only 325 mm wide.

Transformer protection

iSafering offers a choice between a switch fuse combination and circuit breaker with relay for transformer protection. The switch fuse combination offers optimal protection against short-circuits, while the circuit breaker with relay option offers better protection against low overcurrents. Circuit breaker with relay is always recommended for larger transformers.

Normal operation conditions

The rated characteristics of the switchgear are valid under the following ambient conditions:
minimum ambient temperature: - 25 °C
maximum ambient temperature: + 40 °C
For different temperature ranges, please contact your UNISUN sales representative.


Standards

iSafeRing/iSafePlus is tested according to following
IEC-standards:
IEC 62271-1/IEC 62271-100/IEC 62271-102/IEC 62271-103/IEC 62271-105/IEC 62271-200/IEC 60529:
 

SF6 insulated Ring Main Unit Outer assembly
Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit

iSafering outer assembly
Upper front cover
1. Manometer
2. Nameplate module
3. Short circuit indicator
4. Capacitive voltage indication
5. Load break / earthing switch position indicator
6. Push buttons close/open operation
7. Charged spring indicator
8. Self-powered protection relay
9. Vacuum circuit-breaker position
10. Operation shaft
11. Padlock device
Lower front cover
12. Nameplate switchgear
13. Fuse blown indicator
14. Disconnector / earthing switch position indicator
15. Capacitive voltage indication
Cable compartment cover
16. Cable compartment cover standard
17. Cable compartment cover with inspection window
18. Support bar (removable)
Side cover
19. Lifting lug
20. Operating handle (standard on right hand side)
 
Inner assembly
Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
 
1. Mechanism compartment
2. SF6 gas tank
3. Cable compartment
4. Pressure relief area

Technical data
SafeRing C-module F-module V-module
Switch disconnector Earthing switch Switch-fuse disconnector Downstream earthing switch Vacuum circuit-breaker Earthing switch/ disconnector
Rated voltage Kv 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24 12/17,5/24
Rated frequency 5) Hz 50/50/50 50/50/50 50/50/50 50/50/50 50/50/50 50/50/50
Power frequency withstand voltage kV 28/38/50 28/38/50 28/38/50 28/38/50 28/38/50 28/38/50
Lightning impulse withstand voltage kV 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125 95/95/125
Rated normal current A 630/630/630   2001)   200/200/200  
Breaking capacities:              
active load A 630/630/630          
closed loop A 650/650/650          
off load cable charging A 140/140/140          
off load transformer A     20/20/20      
earth-fault A 205/160/160          
earth-fault cable charging A 117/91/91          
short-circuit breaking current kV     see2)   16/16/16  
Making capacity kV 52,5/40/40 52,5/40/40 see2) 12,5/12,5/12,5 40/40/40 40/40/40
Short time current 3 sec. 3) kV 21/16/16 21/16/16     16/16/16 16/16/16
Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit
Mv Switchgear Gas Insulated Switchgear Gis Ring Main Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier