Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
  • Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
Find Similar Products

Basic Info.

Model NO.
RCW-12
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Vcb
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
VDE, ISO9001-2000
Material
Steel
Rating Frequency
50Hz
Rated Current
630-1250A
Transport Package
Wooden
Trademark
Chenghe
Origin
Wenzhou China
Production Capacity
4000 Sets/Year

Product Description

Overview
Description
Our automatic reclosers have rating as defined in ANSI/IEEE Standard C37.60 (I) as summarised below:
Service Conditions:
a. Temperature-up to 45°C.
b. Altitude-up to 1,000 meters.
Rated Voltage 
a. Nominal system voltage-33,000volt
b. Rated maximum voltage -40500 volts.
c. Power frequency withstand voltage-70 KV
Rated frequency - 50 Hertz 
a tolerance of ± 5 percent. Rated symmetrical making current is the same value as the rated symmetrical interrupting current, with asymmetrical relationships as defined in ANSI/IEEE C37.60.
DESIGN
Three phase class III recloser is in accordance with the standard ANSI/IEEE C37.60.
The recloser is designed to provide self-contained 33KV circuit protection with series trip, solenoid operation and electronic control single break contact structure and fault interruption under vacuum. The vacuum interrupters are in accordance with ANSI/IEEE C37.85.  The recloser is accordance with ANSI/IEEE C37.85. The recloser is  designed to sense line-to-ground, line-to-line or three-phase fault currents and interrupt all three phases of the distribution circuit simultaneously. The recloser is equipped with a electronic type ground feature. For fault target, Automatic Circuit recloser will be provided with an indicator for detection of fault current on individual phase or ground. If the Electronic Control cubicle of Reclosers or Recloser itself require an auxiliary transformer, the manufacturer must provide the same at his cost. The recloser is provided with in-built auxiliary transformer of required rating to provide power supply to the control panel.

Specification:
 

N Item Unit Data
1 Rated voltage kV 15 27 38
2 Rated current A 630 630/1250 630/1250
3 Rated frequency Hz 50/60
4 Power frequency 1min Dry kV 55 65 95
Wet 45 55 80
5 Lightning impulse withstand voltage(peak) kV 95/110 125/165 170/200
6 Rated short circuit breaking current kA 16 16 12.5
7 Rated short current switching current(peak) kA 40 40 31.5
8 Rated peak value withstand current kA 40 40 31.5
9 4S short time withstand current kA 16 16 12.5
11 Rated operating circulate   O-0.5S-CO-2S-CO-2S-CO
10 Breaking current frequency under rated short circuit time 200
12 Mechanism life time 10000
13 Secondary loop 1 min power frequency withstand kV 2
Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)
Rcw-12 Series Outdoor Auto Circuit Recloser (ACR)

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier